Products in Single Compressor (Cold Room)
Electrical Panel for Medium Temperature Cold Room (Plastic housing)
CRC-2020 (Pos. Temp, 7.5 to 10HP)
Electrical Panel for Medium Temperature Cold Room (Plastic housing)
CRC-2020 (Pos. Temp, 7.5 to 10HP)
- Capacity: 7.5 to 10HP
- 4 Digit, 1” Dot matrix Display
- 0.1 Resolution for Precise Control
- Auto/Manual Defrost option available
- Time based OFF Cycle Defrost
- HP/LP, OPS, AUX faults for Compressor Protection
- Internal Buzzer for Faults
- Door Open fault Input
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & Protection
- Last 10 Fault Records
- RS-485(Modbus) Connectivity
- FR Grade Plastic Housing
- Application: Medium(Positive) Temp. Cold Room
Electrical Panel for Low Temperature Cold Room (Plastic housing)
CRC-2052 (Neg. Temp, 7.5 to 10HP)
Electrical Panel for Low Temperature Cold Room (Plastic housing)
CRC-2052 (Neg. Temp, 7.5 to 10HP)
- Capacity: 7.5 to 10HP
- 4 Digit, 1” Dot matrix Display
- 0.1 Resolution for Precise Control
- Auto/Manual Defrost option available
- Selectable Time, Temperature based Defrost
- HP/LP, OPS, AUX faults for compressor Protection
- Quick Freeze Mode
- Internal Buzzer for Faults
- Door Open fault Input
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & Protection
- External Buzzer for Faults
- Last 10 Fault Record
- RS-485(Modbus) Connectivity
- FR Grade Plastic Housing
- Application: Low(Negative) Temp. Cold Rooms
Electrical Panel for Medium Temperature Cold Room (Metal housing)
CRC-202000S (Pos. Temp, 7.5 to 10HP)
Electrical Panel for Medium Temperature Cold Room (Metal housing)
CRC-202000S (Pos. Temp, 7.5 to 10HP)
- Capacity: 7.5 to 10HP
- 4 Digit, 1” Dot matrix Display
- 0.1 Resolution for Precise Control
- Auto/Manual Defrost option available
- Time based OFF Cycle Defrost
- HP/LP, OPS, AUX faults for Compressor Protection
- Internal Buzzer for Faults
- Door Open fault Input
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & Protection
- Last 10 Fault Records
- RS-485(Modbus) Connectivity
- Powder coated steel Housing
- Application: Medium(Positive) Temp. Cold Room
Electrical Panel for Low Temperature Cold Room (Metal housing)
CRC-205200S (Neg. Temp, 7.5 to 10HP)
Electrical Panel for Low Temperature Cold Room (Metal housing)
CRC-205200S (Neg. Temp, 7.5 to 10HP)
- Capacity: 7.5 to 10HP
- 4 Digit, 1” Dot matrix Display
- 0.1 Resolution for Precise Control
- Auto/Manual Defrost option available
- Selectable Time, Temperature based Defrost
- HP/LP, OPS, AUX faults for compressor Protection
- Quick Freeze Mode
- Internal Buzzer for Faults
- Door Open fault Input
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & Protection
- External Buzzer Output on Faults
- Last 10 Fault Record
- RS-485(Modbus) Connectivity
- Powder coated steel housing
- Application: Low(Negative) Temp. Cold Rooms
Electrical Panel for Medium Temperature Cold Room (Plastic Housing)
CRC-5022
Electrical Panel for Medium Temperature Cold Room (Plastic Housing)
CRC-5022
- FR Grade Plastic Housing
- Capacity: up to 10HP for 3 Phase, 20 A for Single Phase
- 3 Digit, 2" Display
- Auto/Manual Defrost option available
- Selectable Time, Temperature based Defrost
- HP/LP, SPPR, VPR, AUX fault Inputs for compressor Protection
- Quick Freeze Mode
- Door Open fault Input
- Internal Buzzer for Faults
- Option for configuring Relay as Alarm or Light
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & protection
- Last 10 Fault Records
- RS-485(Modbus) Connectivity
- High & Low Temperature Logs
- Application: Medium(Positive) Temp. Cold Room
3 Phase Cold Room Electrical Panel (Plastic Housing)
CRC-2072
3 Phase Cold Room Electrical Panel (Plastic Housing)
CRC-2072
- 3 phase cold room electrical panel
- Capacity: 10HP
- Auto/Manual Defrost option available
- Selectable Time, Temperature based Defrost
- HP/LP, OPS, AUX faults for compressor Protection
- Quick Freeze Mode
- Temperature controlled by two probe averaging feature (settable)
- Dual Evaporator and two defrost
- HACCP Event Logging
- RTC for defrost, energy saving, data & Fault logging
- SD card for data downloading
- Wi-Fi for IoT and Web Server
- Internal Buzzer for Faults
- R, Y, B Phase Indications & Fault Sensing
- Compressor Current Measurement & Protection
- RS-485(Modbus) Connectivity
- FR Grade Plastic Housing
- Application: Low(Negative) Temp. Cold Rooms